MCB
Home
Products
MCB
Minitures Circuit Breaker MCB (SCHRAK-Austria)
MCB – BM SERIES 4,5 KA
Specfications
Rated voltage/frequency: 230 V/400 V AC 50/60 Hz,
Rated breaking capacity: 4.5 kA according to IEC/EN 60 898
Tripping characteristics: B, C according to EN 60 898
Rated breaking capacity DC: max 48 V one pole
Rated current 6-63A
Number of poles :1Pole,2Poles and 3 Poles
DIN rail mounting (EN 50 022)
Finger and hand touch safe according to BVG A3/OVE-EN 6
MCB – BM SERIES 6 kA
Specfications
Rated voltage/frequency: 230 V/400 V AC 50/60 Hz,
Rated breaking capacity: 6 kA according to IEC/EN 60 898
Tripping characteristics: B, C according to EN 60 898
Rated breaking capacity DC: max 48 V one pole
Rated current 2-63A
Number of poles :1Pole,2Poles,3Poles and 4 Poles
DIN rail mounting (EN 50 022)
Finger and hand touch safe according to BVG A3/OVE-EN 6
MCB – BM SERIES 10 kA
Specfications
Rated voltage/frequency: 230 V/400 V AC 50/60 Hz,
Rated breaking capacity: 6 kA according to IEC/EN 60 898
Tripping characteristics: B, C,D according to EN 60 898
Rated breaking capacity DC: max 48 V one pole
Rated current 2-63A
Number of poles :1Pole,2Poles,3Poles and 4 Poles
DIN rail mounting (EN 50 022)
Finger and hand touch safe according to BVG A3/OVE-EN 6
MCB – HIGH CURRENT BR SERIES 15 – 25 kA
Specfications
Rated voltage/frequency: 230 V/400 V AC 50/60 Hz
Rated breaking capacity: 15-25 kA according to marking
Rated breaking capacity DC: max 60 V one pole
Tripping characteristics: C & D according to EN 60 898
Rated current 20-125A
Number of poles :1Pole,2Poles,3Poles and 4 Poles
DIN rail mounting (EN 50 022)
Finger and hand touch safe according to BVG A3/OVE-EN 6
RCCB – RESIDUAL CURRENT CIRCUIT BREAKER SERIES BC
Specfications
Rated voltage:
6kA: 4P 230 V/400 V AC, 2P 230 V AC 50 Hz
10 kA: 4P 250 V/400 V AC, 2P 250 V AC 50 Hz
Design according to EN 61 008, IEC 1008
Finger protection to BVG A3/ÖVE-EN 6
DIN rail mounting (EN 50 022)
1. Rated breaking capacity: 6 kA :
Rated current (25-63) A
2Poles and 4Poles
Sensitivity trip current 30 mA,100 mA and 300 mA.
2. Rated breaking capacity: 10 kA :
Table for rated current:
MCB – SERIES BMS0-DC
Specfications
Rated voltage: 220 V DC per pole; T = 4 ms
Switching capacity: 6 kA acc. to IEC/EN 60898
Tripping characteristics: C